Troubleshooting
26 Rev 73531i-20100609 E
Troubleshooting
Generator will not start No fuel Add fuel
Faulty spark plug Replace spark plug
Unit loaded during start up Remove load from unit
Generator will not start;
Generator starts but runs roughly
Fill crankcase to the proper level
Place generator on a flat, level surface
Choke in the wrong position. Adjust choke.
Spark plug wire loose Attach wire to spark plug
Generator shuts down during
operation
Fill crankcase to the proper level.
Place generator on a flat, level surface
Generator cannot supply enough
power or overheating
Review load and adjust. See “Power
Management”
Check for air restriction. Move to a
well ventilated area
No AC output Cable not properly connected Check all connections
Connected device is defective Replace defective device
Unplug electrical loads. Turn off
generator. Restart.
Faulty inverter assembly Replace
Inspect and tighten wiring
connections
Other Contact the help line.
Engine governor defective Contact the help line
Repeated circuit breaker tripping
Check for damaged, bare or frayed
wires. Replace defective device